Genesis blowers : we decode their part numbers
Introduced on the market 15 years ago, HydroAir / Balboa Genesis blowers are easily recognizable with their blue polypropylene housing. They are available in several blower powers (400W, 700W, 900W and 1200W) and come in multiple versions, depending on how you want to use it. So you should know which reference to choose (if not, contact us!), the G70-2HN-S (700W heating) or the G90-2NN-S (900W) being among the most popular models.
But do you know what is behind these combinations of numbers and letters? This page is here to help you pick the right blower for your needs on Tubs Parts.
Genesis references have several components
- They all start with a G
- The first two numbers indicate the power option: 50 = 500W, 70 = 700W, 90 = 900W, 120 = 1200W
- The next number gives the voltage option: 1 = 120V - 60Hz, 2 = 230V - 50Hz
- A series of two or three letters specifies the technical specifications: variable speed, heating, etc.
- A last letter refers to the packaging option
- Specific approvals can end the references (for example "-UL", a certification issued by Underwriters Laboratories, one of the most prestigious labels that guarantees the conformity of a product to the safety and quality requirements applicable in the United States and Canada).
Blower features
NN | Standard blower for electronic control/touch pad. |
AN | Pneumatic air switch. Pneumatic on/off blower. |
HN | Standard blower for electronic control/touch pad with built-in heating element to reduce cold air in upstart. |
AH | Pneumatic air switch & heater Pneumatic on/off blower with built-in heating to reduce cold air in upstart. |
VN* | Variable speed Standard blower including variable massage mode and automatic dry-out when using a special touch pad (UK01658A) connected directly to blower. No seperate control panel needed. See functional description under “VH” |
VH* | Variable speed & heater Standard blower including variable massage mode and automatic dry-out when using a special touch pad (UK01658A) connected directly to blower. No seperate control panel needed. The blower has built-in heating element to reduce cold air in upstart. Functional description for preset programme: - Press the on/off button = high speed. - Press the +/- button = in-/decrease blower speed. - Press the ~ button = massage mode “pulsating effect” Automatic stop: blower stops 30 min. after the user has operated one of the buttons for the last time. Drying cycle: 30 min. after manual or auto switch off, the blower starts up at high speed for 2 secs. It then drops to low speed and increases gradually to high speed within 30 sec. The blower will then continue running 4½ min. at high speed to drain remaining water from the pipes. |
ANT* | Pneumatic air switch & 3-speed Pneumatic on/off blower including massage mode, automatic dry-out when using standard pneumatic air switch. See functional description under “AHT”. |
AHT* | Pneumatic air switch, 3-speed & heater Pneumatic on/off blower including massage mode, automatic dry-out when using standard pneumatic air switch. With built-in heating element to reduce cold air in upstart. Functional description for preset programme: 1. Press the pneumatic button = high speed. 2. Press the pneumatic button = medium speed. 3. Press the pneumatic button = low speed. 4. Press the pneumatic button = massage mode “pulsating effect”. 5. Press the pneumatic button = off. Automatic stop: blower stops 30 min. after the user has operated one of the buttons for the last time. Drying cycle: 30 min. after manual or auto switch off, the blower starts up at high speed for 2 secs. It then drops to low speed and increases gradually to high speed within 30 sec. The blower will then continue running 4½ min. at high speed to drain remaining water from the pipes. |
* The preset programme can be changed via jumpers inside the blower to change order of functions or to eliminate the drying cycle. Please refer to the user guide of your blower, or contact us.